Alaris Signature Gold 7130 Infusion Pump

Alaris Signature Gold 7130 Infusion Pump
Cosmed | SKU 7130
Please Call For Pricing : 1-800-507-8244
Availability :In stock
 
(0 reviews)  
Quick Review
Alaris Signature Gold 7130 Infusion Pump at the lowest price. Please call for details.

Flow Rate Range: 0.1 to 999.9 ml/hr in 0.1 ml/hr increments (primary)
0.1 to 270.0 ml/hr in 0.1 ml/hr increments (secondary) 
Volume To Be Infused Range: .1 to 9999.9 ml in 0.1 ml increments (primary)
.1 to 999.9 ml in 0.1 ml increments (secondary) 
Volume Infused Range: 0.0 to 9999.9 ml in 0.1 ml increments 
KVO Flow Rate: 0.1-20.0 ml/hr in 0.1 ml/hr increments 
Alarms: Air in Line
Battery Depleted
Channel Malfunction
Computer Link Failure
Flow Sensor Unplugged
Hold Time Exceeded
Instrument Malfunction
Key stuck
Latch Open
No Upstream Flow Detected
Occlusion Downstream
Occlusion Upstream
Primary Flow Detected during 
Secondary: Set Out
Set Up Time Exceeded 

Case: Impact resistant plastic 
Power Requirements: 100- 120 V~,50/60 Hz, 0.5A,3-wire grounded system (40 watts Max) 
Ground Current Leakage: Tested to UL Standard 544 and CSA C22.2 No. 125 for medical and dental equipment. 
Battery: Rechargeable nickel cadmium. With a new, fully charged battery, the pump will operate for 4 hours nominal at 100 ml/hr for a two channel instrument operating on both channels simultaneously.

Bio-Detek ST430 Foam Wet Gel Electrode Square
$70.00 View
GE MEDICAL DEFIB CABLES 700044-208
$249.00 View
COVIDIEN/MEDICAL SUPPLIES DOVER
$82.95 View
COVIDIEN/SURGICAL DEVICES SURGIPRO
$508.90 View
There have been no reviews


: *
: *
: *
 

Flow Rate Range: 0.1 to 999.9 ml/hr in 0.1 ml/hr increments (primary)
0.1 to 270.0 ml/hr in 0.1 ml/hr increments (secondary) 
Volume To Be Infused Range: .1 to 9999.9 ml in 0.1 ml increments (primary)
.1 to 999.9 ml in 0.1 ml increments (secondary) 
Volume Infused Range: 0.0 to 9999.9 ml in 0.1 ml increments 
KVO Flow Rate: 0.1-20.0 ml/hr in 0.1 ml/hr increments 
Alarms: Air in Line
Battery Depleted
Channel Malfunction
Computer Link Failure
Flow Sensor Unplugged
Hold Time Exceeded
Instrument Malfunction
Key stuck
Latch Open
No Upstream Flow Detected
Occlusion Downstream
Occlusion Upstream
Primary Flow Detected during 
Secondary: Set Out
Set Up Time Exceeded 

Case: Impact resistant plastic 
Power Requirements: 100- 120 V~,50/60 Hz, 0.5A,3-wire grounded system (40 watts Max) 
Ground Current Leakage: Tested to UL Standard 544 and CSA C22.2 No. 125 for medical and dental equipment. 
Battery: Rechargeable nickel cadmium. With a new, fully charged battery, the pump will operate for 4 hours nominal at 100 ml/hr for a two channel instrument operating on both channels simultaneously.